Haier Clean Bench/Laminar Flow

  • Flow Type – Horizontal
  • Voltage/Frequency – 220/50/60;115/60
  • Power(W) – 350
  • Vibration Amplitude (UM) – 2
  • Exhaust Filter Typical Efficiency – H13 HEPA,99.99%@0.3um
  • Average Velocity (M/S) – 0.2-0.4
  • Fluorescent Lamp Intensity(Lux)-  ≥1000
  • Exterior Dimesion (W*D*H) (mm) – 1380*792*1960
  • Exterior Dimesion (W*D*H) (in)- 54.4*31.2*77.2
SKU: N/A Category:
Share

Description

Clean Bench & Laminar Flow(Vertical)

  • Featuring many technologies and authoritative testing certification for reliability
  • Microcomputer intelligent control panel with durable touch buttons
  • Multiple safety protection functions including UV delay start
  • Interlocking function to put an end to incorrect operation
  • Ergonomic design to ensure comfortable operation
  • Memory function to avoid repeated start-up setting
  • Integrated stand with universal casters

High-Efficiency Filter HEPA

High-efficiency HEPA filter with efficiency of 99.99%@0.3μm, provides ISO14644.1 Class V standard clean air, safer and reliable clean air.

304 Stainless Work Surface

The durable and corrosion-resistant 304 stainless steel work table without fixing screws reduces the accumulation of dirt, reducing the risk of contamination.

Ergonomic Design

  • Recessed internal lighting reduces eye fatigue.
  • UV sterilization start-up delay technology prevents injury by UV light. After the UV lamp switch is pressed down, the audible and visual alarm will be activated to remind the operator to leave in time;
  • Pre-set function: This technology includes a pre-set UV sterilization start-up delay function to provide improved working efficiency.

Interlocking Function
There is an interlocking function between illuminating lamp and UV lamp, the UV lamp only works when the illuminating lamp is off. If the UV lamp is on, it can be turned off by pressing the daylight lamp, reducing the risk of incorrect operation.

Memory Function
The UV lamp start-up delay time, sterilization duration, pre-set start time, fan position can be set and saved by user on request for the convenient and quick cabinet start-up.

One-key Operation

  • After the UV lamp switch is pressed, the time function can be activated automatically. The default sterilization time is 30min, which can be adjusted by user within 0~99min on request;
  •  Sterilization pre-set, when pressing the UV lamp, the pre-set lamp will light to remind user that the sterilization pre-set function has been activated and that the sterilization pre-set can be conducted.

Clean Bench & Laminar Flow(Horizontal)

Featuring many technologies and certified to ISO146644.1 Class 5 standard, Haier Biomedical’s clean bench laminar flow units are suitable for a wide range of clean air applications within various sectors including pharmaceutical, clinical, life science research, photoelectric or microelectronics manufacturing.

Product Advantages

  • Efficient damp-proof and fire-proof glass fibre HEPA filter, typical efficiency of ≥99.99%. for ≥0.3μm particulate.
  • ISO14644.1 Class 5 Standard, air cleanliness exceeds that required for Class 5 clean air applications.
  • The industry’s first innovated pre-cleaning function pre-cleans the working area before sample handling to further improve sample/product protection.
  • UV lamp start-up delay time prevents operators from being exposed to potentially harmful ultraviolet light. The pre-set function for the ultraviolet sterilization improves user’s operation efficiency.

Features

  • Recessed internal lighting reduces eye fatigue.
  • One-touch UV lamp operation, ultraviolet light can be set with one single key to automate on/off time and sterilisation time interval from 0 to 24 hours, reducing downtime. Audible and visual alarms remind users to leave, protecting them from UV injury.
  • Inter-lock function provides a safer operation. The fluorescent light and ultraviolet light interlock with each other. The ultraviolet light can only be switched on when the fluorescent light is turned off. When the fluorescent light is on, the ultraviolet light is powered off immediately to minimize any risks.

Ergonomic Design

  • The working surface is 800mm above the floor and suitable for an operator to stand or sit , allowing for flexible working through the day to reduce operator fatigue and make operations comfortable.
  • The delay to start function of the ultraviolet sterilization prevents operators exposure to harmful lighting. When ultraviolet light is switched on, the sound and light alarms will notify operators to leave immediately. The light will come on after 10 seconds to prevent operators from being harmed by the ultraviolet light.
  • The pre-set sterilization function improves productivity. The product has an ultraviolet sterilization pre-set timer function, which provides more rest to users and improves work efficiency.
  • The detachable chassis makes installation and moving convenient. It is equipped with universal casters and adjustable stand with levelling feet for convenient moving and cabinet placement.

 