Haier Biological Safety Cabinet – HR1500-IIA2

  • Working Voltage&Frequency(V/Hz) – 220V 50Hz
  • Power(VA) – 1600
  • Power of Blower(W) – AC 650W
  • Airflow Circulation – 70% Downflow,30% Exhaust
  • Main Filter Typical Efficiency – ULPA ,U15,99.9995%@0.12um
  • Exhaust Filter Typical Efficiency – HEPA ,H14,99.995%@0.3um
  • Exterior Dimension(W*D*H) (mm) – 1680*845*2160
  • Exterior Dimension(W*D*H) (in) – 66.1*33.3*85
Share

Description

Intelligent series microbiological class II safety cabinet, provides protection for the user, sample and environment.

Patented Intelligent Constant Air Velocity Technology
It provides real time monitoring of the air velocity of the working area, compares it with the standard air velocity to keep the air speed constant within the safety cabinet by adjustment of the fan speed via the microcomputer system.
304 Stainless Steel
Curved worksurface ensures reduces chance of contamination and is easy to clean
Digital Microprocessor Control System
Real time display of key parameters – downflow velocity, inflow velocity, airflow volume, static pressure, negative pressure, accumulative running time of fan and UV lamp and remaining life of filter. Visual and audible alarms and UV sterilization function.
Low Noise Safety Energy-Saving Mode
Which reduces noise, conserves energy and improves the service life of the filter. When the human body sensor module detects under the intelligent mode that the person is outside and away from the operating area for over 15 minutes, the microcomputer program will automatically switch the safety
Professional Air-Flow Distribution Module
The safety cabinet provides a more uniform airflow, reduced contamination and noise to <62dB(A).
Ultra-Low Penetration Air Filter System
American AAF (ULPA) filter is tested to a typical efficiency of > 99.9995% for 0.12 micron particles. ULPA filter provides vertical laminar flow to the worktable to protect samples from pollution.
Patented Air Flow Disruption Technology
Utilizes side air design on the upper edge and on both sides of the front window to eliminate ‘blind spots’. This prevents crossflow between inside and outside air, reducing contamination (Patent No. ZL200520125549.X).
Unique Drop-Down Front Glass Window
Can be removed in seconds to enable quick and efficient cleaning of upper sections, limiting downtime.
Removable Arm Rest
Reduces user fatigue and does not interfere with air inflow.